Midwest Technologies, Inc. of Illinois2733 East Ash St. - Springfield, IL 62703Phone 217-753-8424 - Fax 217-753-8426www.mid-tech.comTASC-6000, 6300,
1-4TASC-6000, 6300, 660098-05010Rev. - 11.5 BOOM SECTION “ON/OFF” INDICATORSMID-TECHMIDWEST TECHNOLOGIES, INC.CHEMICAL APPLICATORS123ONOFFAlt.-Rate
1-5TASC-6000, 6300, 660098-05010Rev. - 11.8 GROUND SPEED OVERRIDE SWITCHAn optional ground speed override Switch can be used to temporarily operate t
1-6TASC-6000, 6300, 660098-05010Rev. - 1This page purposely left blank
2-1TASC-6000, 6300, 660098-05010Rev. - 12.0 CALIBRATION AND SET UPThe TASC Control Console must be calibrated for the various sensors used and progra
2-2TASC-6000, 6300, 660098-05010Rev. - 1A. Use the following switch settings to select the desired drive method (You should have to do this only onceu
2-3TASC-6000, 6300, 660098-05010Rev. - 1The display shows the current Standard Application Rate (Oz/Ac or L/Ha) for Pump #1.B. Use the INC/DEC switch
2-4TASC-6000, 6300, 660098-05010Rev. - 12.5 SETTING BOOM WIDTHSThe Mid-Tech TASC Control Console is designed to automatically compensate for changes
2-5TASC-6000, 6300, 660098-05010Rev. - 12.6.1 TYPICAL FLOWMETER CALIBRATION NUMBERS (for water)Standard FlowmetersSIZE SUPPLIER CAL.# SIZE SUPPLIER C
2-6TASC-6000, 6300, 660098-05010Rev. - 1F. Make sure there is enough liquid in the main tank to do the test; start the main carrier pump; rotate the d
2-7TASC-6000, 6300, 660098-05010Rev. - 1B. Use the INC/DEC switch to select the initial distance calibration value suggested. You are now ready to per
TASC MANUAL - CHANGE LOG DATE: Revision PAGES AFFECTED: SW Version:5/26/00 1 New Manual. 3.21II
2-8TASC-6000, 6300, 660098-05010Rev. - 12.8.1 TYPICAL PUMP CALIBRATION NUMBERS, PC#The pump calibration number (PC#) is a value that relates to the v
2-9TASC-6000, 6300, 660098-05010Rev. - 1C. Use the INC/DEC switch to reset the display to zero. Select SET-UP with the Mode Selector switch. The curre
2-10TASC-6000, 6300, 660098-05010Rev. - 1N. REPEAT THIS PROCEDURE (steps B through M) FOR THE REMAINING PUMPS.O. Record the Pump Calibration Numbers
2-11TASC-6000, 6300, 660098-05010Rev. - 1B. DIRECT MEASUREMENT OF THE “PRIME” VALUEActually measuring the amount of fluid needed to prime the injectio
2-12TASC-6000, 6300, 660098-05010Rev. - 1L. Proceed to measure the prime values for the remaining pumps, in sequence, using the procedure outlined in
2-13TASC-6000, 6300, 660098-05010Rev. - 1A. To select the desired response set the console switches to the following positions:Booms OFFInjection pump
2-14TASC-6000, 6300, 660098-05010Rev. - 1CAUTION: When traveling at a speed slower than the GSO speed setting, this feature will cause the Product to
2-15TASC-6000, 6300, 660098-05010Rev. - 12.12.2. REFLOW SET UPBefore operating the sprayer in the Reflow mode, there are some critical set-up steps w
2-16TASC-6000, 6300, 660098-05010Rev. - 1The TASC Console display cycles through its normal Power Up testing routine and momentarily displays the soft
3-1TASC-6000, 6300, 660098-05010Rev. - 13.0. OPERATIONUnder normal operating conditions, TASC is automatic. It performs precisely, according to the i
IIITASC-6000, 6300, 660098-05010Rev. - 1TASC MANUAL - CHANGE LOG ...
3-2TASC-6000, 6300, 660098-05010Rev. - 13.4. CHANGING THE APPLICATION RATE “ON THE GO”TASC allows the operator to change the Application Rate of the
3-3TASC-6000, 6300, 660098-05010Rev. - 1command is cancelled, TASC resumes controlling the injection application rate according to the target rate est
3-4TASC-6000, 6300, 660098-05010Rev. - 13.6. GROUND SPEED OVERRIDEAn optional Ground Speed Override Switch can be used to temporarily operate the spr
3-5TASC-6000, 6300, 660098-05010Rev. - 13.8. MANUAL OVERRIDE OF FLOW CONTROL VALVEThere may be times when it will be necessary to control the product
3-6TASC-6000, 6300, 660098-05010Rev. - 1This page purposely left blank
4-1TASC-6000, 6300, 660098-05010Rev. - 14.0. MAINTENANCEMid-Tech recommends the following maintenance to keep your TASC system operating at peak effi
4-2TASC-6000, 6300, 660098-05010Rev. - 1If the tubing has been changed, the pump must be calibrated to ensure system accuracy. Use the field calibrati
4-3TASC-6000, 6300, 660098-05010Rev. - 14.6. FLOW CONTROL VALVEPrior to each day’s spraying, the flow control valve should be inspected to ensure the
4-4TASC-6000, 6300, 660098-05010Rev. - 1This page purposely left blank
5-1TASC-6000, 6300, 660098-05010Rev. - 1ERROR CODE CAUSE REMEDY5.0 TASC ERROR MESSAGES, COMMON CONDITIONS AND SOLUTIONSFIRST Check the battery connec
IVTASC-6000, 6300, 660098-05010Rev. - 13.0. OPERATION ...
5-2TASC-6000, 6300, 660098-05010Rev. - 1Err 3(PUMP-F)(Cont.)(PUMP-1,2,3)Liquid injectionpumpsErr 4PUMP-1,2,3TASC ERROR MESSAGES, COMMON CONDITIONS AND
5-3TASC-6000, 6300, 660098-05010Rev. - 1This is often caused by loss of powerto the valve.Incorrect switch sequence is selected onthe console.Communic
5-4TASC-6000, 6300, 660098-05010Rev. - 1This page purposely left blank
6-1TASC-6000, 6300, 660098-05010Rev. - 16.0. EMERGENCY OPERATIONSMIDWEST TECHNOLOGIES has strived to make TASC as fool proof and reliable as possible
6-2TASC-6000, 6300, 660098-05010Rev. - 16.2. FLOW CONTROL VALVE FAILUREThe TASC can still be operated in the event of a flow control valve failure. T
6-3TASC-6000, 6300, 660098-05010Rev. - 1E. Turn ON the desired chemical injection pumps, to the rate desired, proceed to the application area, acceler
6-4TASC-6000, 6300, 660098-05010Rev. - 1This page purposely left blank
A-1TASC-6000, 6300, 660098-05010Rev. - 1APPENDIX-ASYSTEM DRAWINGSA.0 SYSTEM DRAWINGS
A-2TASC-6000, 6300, 660098-05010Rev. - 1TASC-6300 WIRING DIAGRAMMIDWEST TECHNOLOGIES, INC.M-T 98251WRC+Vehicle Battery(12 Volts)TASC-6300 CONSOLEPump
A-3TASC-6000, 6300, 660098-05010Rev. - 1TASC-6600 Control SystemCarrier PumpBoom Valves(Up to 9 Total)CarrierTank FLOW METER In-Line FilterAUTO-RANGEF
VTASC-6000, 6300, 660098-05010Rev. - 1C.0. INSTALLATION ...
A-4TASC-6000, 6300, 660098-05010Rev. - 1To Spray BoomsBoom ValvesTwo wayBYPASS ADJUST VALVE INJECTION PUMP ASSEMBLIESQuick Fill PortCHEMICAL TANK ASSE
A-5TASC-6000, 6300, 660098-05010Rev. - 11/8 Pint = 2 Fluid Ounces1/4 Pint = 4 Fluid Ounces1/3 Pint = 5.33 Fluid Ounces1/2 Pint = 8 Fluid Ounces2/3 Pin
A-6TASC-6000, 6300, 660098-05010Rev. - 1TASC 150 - 3/8" TubePUMP/TUBE SELECTION CHART for TASC SERIES PUMPS 7.4TASC 350 - 1/2" Tube370 4.422
B-1TASC-6000, 6300, 660098-05010Rev. - 1APPENDIX-BSYSTEM OVERVIEW
B-2TASC-6000, 6300, 660098-05010Rev. - 1B.0. SYSTEM OVERVIEWMid-Tech has drawn upon many years of experience in electronically controlled chemical a
B-3TASC-6000, 6300, 660098-05010Rev. - 1B.1.2. HOW A TASC-6300 AND 6600 CONTROLS CHEMICAL APPLICATION RATEThe theory behind controlled, chemical inje
B-4TASC-6000, 6300, 660098-05010Rev. - 1B.2. TASC SYSTEM COMPONENT PARTSThere are seven major components in a complete TASC Injection Control System,
B-5TASC-6000, 6300, 660098-05010Rev. - 1B.2.3. FLOW CONTROL VALVETASC requires a flow control valve in the main boom supply line to provide automatic
B-6TASC-6000, 6300, 660098-05010Rev. - 1B.2.7. CHEMICAL CONTAINERSMIDWEST TECHNOLOGIES has designed special chemical containers for use with chemical
C-1TASC-6000, 6300, 660098-05010Rev. - 1APPENDIX-CINSTALLATION
VITASC-6000, 6300, 660098-05010Rev. - 1This page purposely left blank
C-2TASC-6000, 6300, 660098-05010Rev. - 1C.0. INSTALLATIONC.1. CONTROL CONSOLE INSTALLATIONThe Control Console should be located inside the vehicle c
C-3TASC-6000, 6300, 660098-05010Rev. - 1C.1.2. CONSOLE CABLE ROUTINGConsole Cable routing is important. There are up to eleven connector positions on
C-4TASC-6000, 6300, 660098-05010Rev. - 1C.2. FLOWMETER INSTALLATIONThe installer should refer to the detailed instructions shipped with the particula
C-5TASC-6000, 6300, 660098-05010Rev. - 1C.3. FLOW CONTROL VALVE INSTALLATIONThere are a number of different types of flow control valves capable of o
C-6TASC-6000, 6300, 660098-05010Rev. - 1pump switch is not used, the shorting plug must be installed or TASC will not operate. The optional Ground Spe
C-7TASC-6000, 6300, 660098-05010Rev. - 1C.6.2. INJECTION PUMP LOCATIONInjection pumps must be located as close as possible to the point where the che
C-8TASC-6000, 6300, 660098-05010Rev. - 1C.6.5. PRECISION PERISTALTIC INJECTION PUMP TUBING INSTALLATIONEach injection pump comes with two appropriate
C-9TASC-6000, 6300, 660098-05010Rev. - 1C.7. CHEMICAL CONTAINERSMid-Tech tanks are ideal containers for handling raw chemicals. Alternative container
C-10TASC-6000, 6300, 660098-05010Rev. - 1The Mid-Tech tanks comes complete with a chemical resistant, quick disconnect coupler. The product line betwe
D-1TASC-6000, 6300, 660098-05010Rev. - 1APPENDIX-DROADSIDE/HANDGUNOPERATION
1-1TASC-6000, 6300, 660098-05010Rev. - 11.0 SWITCHES AND CONTROLSMID-TECHMIDWEST TECHNOLOGIES, INC.CHEMICAL APPLICATORS123ONOFFAlt.-RateTASC-6600TOT
D-2TASC-6000, 6300, 660098-05010Rev. - 1D.0. TASC ROADSIDE/HANDGUN OPERATIONTASC roadside spraying operations require a special boom control switchbo
D-3TASC-6000, 6300, 660098-05010Rev. - 1D.2. HANDGUN MODE OPERATIOND.2.1. HANDGUN MODE, SET-UP FUNCTIONSTo put the TASC in the Handgun mode:A. Set t
D-4TASC-6000, 6300, 660098-05010Rev. - 1D.2.3. HANDGUN MODE, SPECIAL CONSIDERATIONS:A. Pump Calibrations: The speed of the injection pumps during cal
D-5TASC-6000, 6300, 660098-05010Rev. - 1D.2.5. HANDGUN MODE, MANUAL VALVE OVERRIDE:The flow control valve can be set to a manual override condition,
D-6TASC-6000, 6300, 660098-05010Rev. - 1D.2.7. HANDGUN MODE, PRINTER OUTPUT SAMPLESThe following two sample printouts show the typical printouts in t
D-7TASC-6000, 6300, 660098-05010Rev. - 1Monitoring a pressure gauge, use the INC/DEC switch to set the desired pressure. You are now set to operate at
D-8TASC-6000, 6300, 660098-05010Rev. - 1+Vehicle Battery(12 Volts)TASC-6300 CONSOLEPump ControlCablesGround Speed Sensor120-0000-KITChemical Injection
D-9TASC-6000, 6300, 660098-05010Rev. - 1+Vehicle Battery(12 Volts)TASC-6300 CONSOLEPump ControlCablesGround Speed Sensor120-0000-KITChemical Injection
D-10TASC-6000, 6300, 660098-05010Rev. - 1This page purposely left blank
1-2TASC-6000, 6300, 660098-05010Rev. - 11.4.1 DISPLAY SELECTOR FUNCTIONS IN OPERATE MODE(Refer to Appendix D for these switch functions in "Hand
1-3TASC-6000, 6300, 660098-05010Rev. - 11.4.2 DISPLAY SELECTOR FUNCTIONS IN SET UP MODE(Refer to Appendix D for these switch functions in "Handg