Teejet TASC-6100 Manual do Utilizador Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 86
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
2-3
98-05018
R2
CE & StandardVersion
TASC 6100
Setup
& Cal.
Setting the APPLICA-
TION RATE to 0.0 will
turn off the flow
control function.
DISPLAY SELECTOR
Speed
Area Impl. Width
Distance
Test
Speed
PSI/Prime
Total Applied
Application Rate
OFF SET- UP DEC.
ON
OPERATE INC.
Scan
Product Vol.
Fan RPM
BOOMS
123456789
% Rate
A-1
A-2
A-3
B
Alt.-Rate
Standard Rate
OFF
A-4
DISPLAY SELECTOR
Speed
Area Impl. Width
Distance
Test
Speed
PSI/Prime
Total Applied
Application Rate
OFF SET- UP DEC.
ON
OPERATE INC.
Scan
Product Vol.
Fan RPM
BOOMS
123456789
% Rate
A-1
A-2
A-3
B
Alt.-Rate
Standard Rate
OFF
A-4
LIQUID/GRANULAR COMMON SETUP ITEMS
SETTING APPLICATION RATES
T
he TASC 6100 system is designed to maintain a
constant, pre-selected application rate. In order for
the control console to do this, the operator must
enter the desired application rate. Two, switch selectable,
rates can be pre-programmed into the console.
Standard Rate
A. Set the console switches to the following positions:
1. Power ON
2. Mode Selector OPERATE
(APPLICATION RATE IS SET IN THE OPERATE MODE!!!)
3. Display Selector Application Rate
4. Rate switch Standard Rate
The display shows the current application rate.
B. Use the INC./DEC. switch to set the desired rate.
Alternate Rate
C. Set the console switches to the following positions:
1. Power ON
2. Mode Selector OPERATE
(APPLICATION RATE IS SET IN THE OPERATE MODE!!!)
3. Display Selector Application Rate
4. Rate switch Alt.- Rate
The display shows the current application rate.
D. Use the INC./DEC. switch to set the desired rate.
SETTING THE % RATE CHANGE
T
his feature allows the operator to change the
application rate ON THE GO with a simple
actuation of the INC./DEC. switch. The amount of
change each switch actuation makes is proportional to
the value programmed into this position, (e.g. 20 =20%