2.0 BAR. This is the value to enter into the console as the
pressure sensor cal. #. For example, in the following chart,
for a 8002-SS nozzle, the row for 2.0 BAR and column
for 10 KPH cross at 78.0 Liters per Hectare, the pressure
sensor cal. # for this particular nozzle.
NOTE: You must use the 2.0 BAR / 10 KPH value
regardless of the speed and pressure at which you are
operating.
Use the circled number for the pressure sensor calibra-
tion number.
Entering The Flow Sensor Calibration Number
Use the following procedure to enter the flow sensor
calibration number.
A. Set the console to the following positions;
1. Power ON
2. Mode Selector SET- UP
3. Display Selector Total Applied
4. Master switch OFF (ON If using
/Booms Pump L rEFLO)
B. Use the INC./DEC. switch to set the desired flow
sensor calibration number.
NOTE: If the console is in Reflow Mode (Pump L
rEFLOW), the flowsensor cal. # can only be viewed
or changed when all programmed booms are on.
DISPLAY SELECTOR
Speed
Area Impl. Width
Distance
Test
Speed
PSI/Prime
Total Applied
Application Rate
OFF SET- UP DEC.
ON
OPERATE INC.
Scan
Product Vol.
Fan RPM
BOOMS
123456789
% Rate
A-1
A-2
A-3
B
MASTER
ON
OFF
MI
A-4
If using "Pump L rEFLO"
If using "Pump L STnrd"
or "Pump L PSi"
Liters per Hectare
Liquid Capacity 50 cm Spacing
Pressure in 7 8 10 12
Tip No. in bar l/min km/h km/h km/h km/h
2.0 0.65 111 97.5 78.0 65.0
TP8002-SS 2.5 0.72 123 108 86.4 72.0
3.0 0.79 135 119 94.8 79.0