Vista de página 22
2-7
98-05018
R2
CE & StandardVersion
TASC 6100
Setup
& Cal.
G. Stop the vehicle at the measured distance end marker.
Compare the distance indicated by the console to the
actual measured distance, to determine how much
correction is necessary. For example: if the indicated
distance is 396 Ft. after driving over a 400 foot
range, the error in the distance calibration is 1.0%.
H. Calculate the new distance calibration number using
the following formula:
Example:
NOTE: Use the same equation, regardless of the type of
distance sensor .
I. Enter the corrected cal. # using the switch settings
shown in the GENERAL CONSIDERATIONS AND INITIAL
CALIBRATION NUMBERS section above. Switch back to
the OPERATE mode. The distance accumulator
should now agree with the measured distance that
you traveled. If it doesn't , recheck your calculations.
RECORD THIS CALIBRATION NUMBER
ON
LAST PAGE OF MANUAL.
SETTING THE HOLD/CLOSE RESPONSE OF THE FLOW
CONTROL VALVE
T
he operator can select a "Hold" or "Close" response
of the flow control valve to both Implement
Status switch and All Booms OFF" conditions.
These responses are independent of each other, allowing
the operator to select a "Hold" condition for one and a
"Close" for the other. Careful consideration should be
given to both conditions and the response selected for
your application.
Implement Status Switch
When the operator selects the "Hold" condition, deactiva-
tion of the Implement Status switch (open circuit) holds
the flow control valve in its current position. When
Measured distance
Indicated distance
x Old DC# = New DC#
400
396
x 760 = 768, the New DC#